background image

     

--7-- 

 

 

 

 

 

Declaration of Conformity: 

In accordance with the provisions of Directives 2014/35/EU, 2014/30/EU, 2009/19/EC, this 

product complies with the following standards or normative documents: 

EN55014-1;  EN55022 B;  EN61000-6-1;  EN61000-4-2;  EN61000-4-3;  EN61000-4-4;   

EN62368-1;  EN50498.

 

 

The product 

must not be 

disposed of in 

the household 

waste. 

 

The product is RoHS compliant. 

It complies with the directive 

2011/65/EU for Reduction of 

Hazardous Substances in electrical 

and electronic equipment. 

 

 

 

 

 

 

Safety Regulations: 

The Battery Protector 100 had been designed according to the valid safety regulations. 

Appropriate application is restricted to: 

 

Deep discharge protection for batteries with the specified nominal voltage. 

 

The indicated voltage rates, current rates and cable cross-sections of the cabling. 

 

Installation of the indicated fuses near the battery to protect the cabling of the unit. 

 

Technically faultless condition. 

 

Installation in a well-ventilated room, protected from rain, humidity, dust, aggressive battery gases, as well as in 

an environment being free from condensation water. 

 

For lithium batteries, the unit is not suitable as substitute for a BMS safety system of the battery! 

 

The unit is not applicable as safety relay (emergency off switch) for disconnection of dangerous machines or 

drives.  

 

Never connect the unit between starter battery and the electric/electronic system of the vehicle. 

 

Never use the unit in locations where the risk of gas or dust explosion exists! 

 

Observe the safety regulations. 

 

Open-air operation of the unit is not allowed.

 

 

Cables are always to be laid in such a way that damage is excluded. Observe to fasten them tightly.

 

 

Never lay 12 V (24 cables and 230 V mains supply cables into the same cable conduit (empty conduit).

 

 

Check live cables or leads periodically for insulation faults, points of break or loosened connections. Occurring 

defects must be remedied immediately. 

 

The unit is to be disconnected from any connection prior to execution of electrically welding or work on the electric 

system. 

 

If the non-commercial end-user is not able to recognize the characteristic values being valid for a unit or the 

regulations to be observed, a specialist is always to be consulted. 

 

The user/buyer is obliged to observe any construction and safety regulations. 

 

The unit is not equipped with parts, which can be replaced by the user

 

Keep children away from batteries and connections. 

 

Observe the safety regulations of the battery manufacturer. 

 

Ventilate the battery room. 

 

Non-observance may result in injury or material damage. 

 

The warranty period is 36 months from the purchase date (against presentation of the sales slip or invoice). 

 

The warranty will be void in case of any inappropriate utilisation of the unit, if it is used beyond the technical 

specification, in case of improper operation or external intervention. We do not assume any liability for any damage 

resulting hereof. The liability exclusion is extended to any service being executed by third, which has not been 

ordered by us in writing. Service is to be effected exclusively by VOTRONIC Lauterbach.

 

Summary of Contents for Battery Protector 100

Page 1: ...ry alarm as soon as the switch off level is reached Visual indication of the operating state Audible indication in case of preliminary alarm and disconnection can be deactivated optionally Output for external alarm indication max 0 2 A short circuit proof Input for separate sensor line for unfalsified measurement of the battery voltage Immediate emergency shut down in case of defective battery or ...

Page 2: ... controller generator charging converter etc are connected directly to the battery to ensure battery charging even with switched off battery protector Powerful inverters with own low voltage disconnection are also connected directly to the battery Option Operation with Sensor Line Sensor Selector Switch 6 Sens Set Batt to position ON Particularly in case of powerful consumer loads being equipped w...

Page 3: ...he preliminary alarm will be reset If a low voltage disconnection had been released for all that restart can be effected Automatically according to the connection voltage rates which are listed in the table charging mode or Manually at any time by means of the key EMERGENCY ON OFF or remote switch OFF and again ON Key EMERGENCY ON OFF The laterally installed key allows the following functions 1 Ma...

Page 4: ...delay times or automatic switching threshold 3 2 1 Disconnection Voltage 24 V Connection Voltage 21 2 V 40 s 24 8 V 1 s x 23 0 V 40 s 25 0 V 1 s x 23 6 V 40 s 25 6 V 1 s x x Automatic 25 0 V 2 s 3 2 1 Disconnection Voltage 12 V Connection Voltage x 10 6 V 40 s 12 4 V 1 s x x 11 5 V 40 s 12 5 V 1 s x x 11 8 V 40 s 12 8 V 1 s x x x Automatic 12 5 V 2 s The unit can extend the lifetime of Lithium LiF...

Page 5: ...rs for the correct disconnection voltage and the time If a battery is permanently discharged with only small current rates disconnection must be effected in case of higher voltage levels By this method the cells are protected from degenerative changes and lasting damages at the electrodes The disconnection will be effected at 12 2 V in 4 weeks Consumer loads with large current draw will cause a qu...

Page 6: ...rs are protected by disconnection of the supply voltage at 15 5 V 31 5 V Reconnection is effected 20 seconds after a drop below this voltage level If such high voltage levels will be reached repeatedly the charging controller the battery the charger and the battery terminals should be checked Lifetime of the battery The battery protector 100 can extend the lifetime of the battery considerably The ...

Page 7: ...of gas or dust explosion exists Observe the safety regulations Open air operation of the unit is not allowed Cables are always to be laid in such a way that damage is excluded Observe to fasten them tightly Never lay 12V 24cables and 230 V mains supply cables into the same cable conduit empty conduit Check live cables or leads periodically for insulation faults points of break or loosened connecti...

Page 8: ...ing PNP maximum 0 2 A Internal fuse 1 A self resetting after disconnection of the consumer Output Voltage During Alarm active 12 V 24 V Voltage at terminal Battery minus approx 0 3 V Output Voltage without Alarm not active 0 V Fitting Position of Unit any Working Temperature Range 20 45 C Protection Class IP21 Dimensions mm 105 x 77 x 38 mm Weight 180 g Ambient Conditions Humidity of Air max 95 RH...

Reviews: