Diagnostics:
Enter Bank 3 and turn on selectable feature # 7 as described in the feature selection
and setting section.
Exit the feature selection mode then press and hold the pushbutton valet/program switch
and then turn the ignition switch to the on position.
NOTE:
Diagnostic mode is a temporary mode. Once you have accessed the diagnostic
mode, the unit will pause for two seconds then begin to flash the last stored
shut down code. This code will be displayed three times in succession, then
the unit will automatically exit the diagnostic mode.
The parking lights will flash a number of times indicating the reason for the last remote
start shutdown. The light flash indications are as follows:
1 Flash
Run timer expired
2 Flashes
Low or no tach signal (RPM)
3 Flashes
Positive inhibit wire activation
5 Flashes
RF shutdown signal received, or manual start trigger wire reactivated.
6 Flashes
High tach signal (RPM)
7 Flashes
Tach signal has not been learned
8 Flashes
Negative inhibit wire activation
4 PIN DATA BUS PORT (DBI Port)
The 4 pin port located on the side of this module is for proprietary Audiovox data bus
interface modules. These modules are used to access a variety of features in the vehicle
which can be as simple as door trigger inputs, to more complex door lock outputs, or
transponder interfaces for remote starting. DO NOT connect anything to this port other
than the Audiovox DBI interface modules or damage to the Remote Start will occur.
All installation instructions for the DBI modules will be packaged with the individual
component along with the proper 4 pin wiring harness requires to access the data
transmit & receive as well as the proper voltage levels for the interface.