CABLE CLAMP REMOVAL AND INSTALLATION
PART # 410 130 XXX
TOOLS REQUIRED
Phillips Head Screwdriver
REMOVAL INSTRUCTIONS
1. Remove the two 4-40 x 1.5″screws and strain relief bar from
the i2 Micro iCon ITA cover (
Figure A
).
INSTALLATION INSTRUCTIONS
1. Install the two 4-40 x 1.5″ screws and strain relief bar from
the ITA cover (
Figure A
).
2. Slowly alternate tightening the 4-40 x 1.5″ screws until the
strain relief bar is snugly against the cable bundle
(
Figure B
).
NOTE:
Reverse the orientation of the strain relief bar to
accommodate smaller cable bundles.
Figure A. Removal/Installation of the strain relief bar.
FORMULA TO CALCULATE THE MAXIMUM
NUMBER OF WIRES IN A CABLE BUNDLE
B = 1.2
√(N
1
d
1
2
+ N
2
d
2
2
. . . +N
n
d
n
2
)
WIRE TYPE
Ø [in]
# WIRES
BUNDLE Ø [in]
26AWG 16878/4
0.043
221
0.77
24AWG 16878/4
0.048
177
0.77
22AWG 16878/4
0.054
141
0.77
M27500-26ml2t08
0.114
31
0.76
M27500-24ml2t08
0.126
26
0.77
M27500-22ml2t08
0.140
21
0.77
M27500-22ml1t08
0.087
54
0.77
22AWG 16878/4 T/P
0.108
35
0.77
24AWG 16878/4 T/P
0.096
44
0.76
NOTE:
Acceptable bundle dimension must be reduced when using
sleeving and shrink tubing.
Figure B. Cable clamp exit area.
Flatten larger wire
bundles to fit oblong
cable exit
B = Wire
Bundle
Diameter
N
1
= Quantity of
first wire type
N
2
= Quantity
of second wire
type
N
n
= Quantity of
n
th
wire type
d
1
= Outside Diameter
of first wire type
d
2
= Outside Diameter
of second wire type
d
n
= Outside Diameter
of n
th
wire type