SECTION 3. 

General Specifications 

Performance 

Full Scale Input  

 

3.0 to +3.0 mV/V full bridge 

Dead Load Range  

 

± 100% of full scale input 

Calibration Range  

 

0.2 to 2.5 mV/V for nominal output 

Linearity  

 

 

0.01% of full scale output 

Common Mode Rejection  

120 dB minimum 

Common Mode Input    

±20% of excitation voltage 

Temperature Stability    

50 ppm/°C 

Response Time  

 

<100 ms 

Input Impedance  

 

>250 Mohms nominal 

Environment 

Operating Temperature   

0 to 55°C (32 to 131°F) 

Storage Temperature    

-25 to 55°C (-13 to 131°F) 

Humidity  

 

 

85% at 55 degrees C 

Atmosphere  

 

 

nonflammable and noncorrosive 

Transducer Supply 

Excitation  

 

 

10 volts DC (symmetric ±5V) 

Gage Resistance  

 

175 -1000 Ohms 

Gage Type  

 

 

foil (2-3mV/V), full bridge 

Number of load cells 

 

 two (2) per tension zone 

Power Supply 

Input    

 

 

24 VDC, +/-5% @ 125 mA 

Range    

 

 

20 to 30 VDC 

Analog Output Signals 

Voltage  

 

 

0-10 VDC @ >2K Ohms 

Current  

 

 

4-20mA @ < 700 Ohms 

Galvanically Isolated  

 

Yes 

Interface 

Panel indicator or PLC input 

Enclosure 

Type    

 

 

DIN-Rail mount 

Overall Size  

 

 

45 x 75 x 105 mm L x H x D (1.77 x 2.95 x 4.13 in) 

Weight   

 

 

185 grams (6.5 oz) 

Terminals 

Approvals 

CE  

 

 

 

conforms to IEC 61326 

Operating Conditions 

Pollution  

 

 

pollution degree 2 

Protection  

 

 

IP20 enclosure 

Ordering information 

The basic Unit part number is PS1010T. 

 

Note: Data and specifications are subject to change without notice. 

Summary of Contents for BLH NOBEL PS1010T

Page 1: ......

Page 2: ...for any particular purpose BLH Nobel shall not be held liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this publication or its contents BLH Nobel reserves the right to revise this manual at any time and to make changes in the contents hereof without obligation to notify any person of such revision or changes ...

Page 3: ...ON 1 Introduction 1 SECTION 2 Description 1 SECTION 3 General Specifications 2 SECTION 4 Installation 3 4 1 PS1010T connections 4 4 2 Mounting 4 SECTION 5 Calibration Procedure 5 5 1 Procedure 5 SECTION 6 Field Engineering 6 ...

Page 4: ...r provides the user with a selectable voltage or current output directly proportional to the load cell input signal The DC analog current output supports sourcing via an external pull down resistor current mode operation only The transmitter is designed to operate from a single DC power supply in the range of 20 to 30 V nominally 24 VDC The PS1010T unit is easily configured and calibrated via push...

Page 5: ...ble and noncorrosive Transducer Supply Excitation 10 volts DC symmetric 5V Gage Resistance 175 1000 Ohms Gage Type foil 2 3mV V full bridge Number of load cells two 2 per tension zone Power Supply Input 24 VDC 5 125 mA Range 20 to 30 VDC Analog Output Signals Voltage 0 10 VDC 2K Ohms Current 4 20mA 700 Ohms Galvanically Isolated Yes Interface Panel indicator or PLC input Enclosure Type DIN Rail mo...

Page 6: ...x for big terminals and 18 AWG max for small terminals There should be provision to ground the cable shields to local Mecca ground e g ground terminal on the DIN rail The installation location should be free of vibration The transmitter should not be located next to strong electrical fields and should have easy access to the module The supply voltage should be protected from a short circuit via fu...

Page 7: ...ut SEN Positive sense input Power Analog output connection Terminal Description 4 20 mA 4 20 mA current output signal ISO COM Isolated common return for current and voltage output signal 0 10V 0 10V voltage output signal COM Supply voltage return Vin Supply input voltage 4 2 Mounting The PS1010T transmitter has a slotted back panel for standard 35 mm DIN Rail mounting Figure 2 shows the PS1010T me...

Page 8: ...want to interrupt the calibration process do not perform the save command You can always recall the last saved calibration data by pressing simultaneously the GAIN and ZERO or power down and up the unit Notes Note that every time a calibration push button is pressed the yellow LED is turned on If the push button is pressed one time it causes the transmitter output signal to increment or decrement ...

Page 9: ...T based web tension measurement systems and or train factory personnel to do so The field service department at BLH is the most important tool to assure the best performance from your application Field service phone numbers are listed below Factory Main Number 781 298 2000 Canada 416 251 2554 or 800 567 6098 in Canada ...

Page 10: ......

Page 11: ......

Page 12: ...blhnobel com ...

Reviews: