33
2. Depressurise the air suspension systems
Ensure the air pressure system is fully depressurised to avoid movement in the suspension
when the air pipe is cut
3. Reconnect the sensor to the internal domain cable
It is recommended that self amalgamating tape is wrapped around
the air transducer connector and a little way up the cable to provide
protection
4. Cut the air pipe at the appropriate position
5. Cut 1” of pipe off the cut end of the
air pipe
6. Clean any dirt from the ends of the air
pipe
7. Connect the air pipe to each side of
the air pressure transducer. Push-fit
until you hear two clicks to lock the
pipe into the pipe fittings
8. Connect the internal domain cable to the cable chain