PARAMETRS
MINIMUM
TYPICAL
MAXIMUM
UNIT
On screen
display of weight
kg/lb.
Overload alarm-
audible
YES
Alarm output level
(at 24VDC)
≥85
dB(A)
Password
protection
4 digits, engineer and manager PIN
Load deliver
capability
NO
TRANSDUCERS
Transducer types
Up to 4 axle/air transducers
INTERFACES
RS232
No of ports
2
Type
Microfit 24 way connector
Baud rate
9600, 19200, 38400, 57600, 115200
CAN
YES
No of ports
2
Baud rate
250
KBS
DIGITAL I/O
Inputs
NO
Outputs
YES
No of outputs
2
Output No
1
Type
EXT_ALM
Negative
Output No
2
Type
EXT_AUX_OUT
Positive
Voltage
9-36
VDC
Current
1
A
ACCESSORIES AND OPTIONS
Barrier control
NO
Printer capability
NO
Adjustable
bracket
YES
VanWeigh
®