Pump-Out Mode:
Your tank must have liquid in it, your hose must be connected
to the top right camlock and your valves need to be in the configuration shown
when you are using the pump to transfer liquid from the sprayer to another tank
outside of the sprayer. One common mistake here is that the bypass valve (top
right) gets left open, which will still allow the pump-out to work, but it will be
substantially slower than if it is set up properly as shown.
Filter
Each sprayer is equipped with a filter right before where the liquid enters the pump.
Inside is a stainless steel 30 mesh filter that is reusable. If you suspect it is clogged,
close your tank valve and loosen the collar around the filter housing, pull outer housing
off and remove the filter. Rinse clean and place back in the housing.