background image

Summary of Contents for VT 1900

Page 1: ...Distributed in the U S A by VTECH Communications 8770 SW Nimbus Avenue Beaverton Oregon 97008 Distributed in Canada by VTECH Electronics Canada Ltd Suite 200 7671 Alderbridge Way Richmond B C V6X 1Z9 Copyright 1996 for VTECH COMMUNICATIONS LTD 91 4032 10 00 ISSUE0 DIGITAL 9OOMHZ CORDLESS PHONE MODEL VT 1900 VT 1900 ...

Page 2: ...8 Extension in use Indicator 18 Volume Controls 18 Flash 18 Redial 18 Hold 18 Mute 18 Ringer Mute 18 Page 18 ADVANCED FUNCTIONS 19 Temporay Tone 19 ProgrammingThe Ringer 19 Changing Ringer Types 19 Turning Off The Ringer 20 CheckingThe RingerType 20 MEMORY DIALING 21 Storing Speed Dial Numbers 21 Memory Dialing 21 Quick Memory Dialing 21 Storing Numbers Using Redial 22 Dialing From Memory 22 Chang...

Page 3: ...battery to provide operational backup in case of power failure In this way you have access to all normal phone functions during a total power outage Calls can still be placed and received without interruption Morethan5 hours backup will be possible with a fully charged battery in the base unit The VTech VT1900 also informs you that another extension is currently off hook on the same phone line The...

Page 4: ...0 267 4 Mounting screws for wall mounting 7377 5 Wall mount accessory HANDSET u BASE UNlT AC POWER ADAPTOR SPEED DIAL INDEX TELEPHONE LINE CORD WALL MOUNTING BRACKET BATTERY PACK WALL MOUNTING SCREWS and CAPS CHARGING CONTACTS ANTENNA VOLUME UP DOWN LOW BAlTERYiMUTE INDICATOR PHONE INDICATOR HOLDKEY OFF KEY PHONE KEY DIALING KEYS 0 9 BATERY COMPARTMENT TONE TemporaryTone REDIAL FLASH MUTE QUICK ME...

Page 5: ... Electronicsat 1 800 267 7377 For repairlwarranty information The telephone company may ask you to disconnectthisequipmentfromthe line network until the problem has been corrected FCC Part 15 Warning Changesor modificationsto this unit not expresslyapprovedby the partyresponsibleforcompliancescould void the user s authorityto operatethe equipment The equipment has been tested and foundto complywit...

Page 6: ...quirementthatthe sum of the load numbers of all devices not exceed 100 Notice Tbe Industry Canada label identifies certified equipment This certification means that the equipment meets certain telecommunications network protective operational and safety requirements The Department does not guarantee the equipment will operate to the user s satisfaction Beforeinstallingthis equipment users should e...

Page 7: ...t but take it to a qualified service personnel when some service or repairwork is required Openingor removing covers may expose you to dangerous voltages or other risks Incorrect reassembly can cause electric shock when the appliance is subsequently used 12 Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following condition A When the power sup...

Page 8: ...ode IMPORTANT Do not dispose of this battery into household garbage For informa tion onrecyclingor properdisposal consult your local solid waste col lection or disposal organization 3 Do not open or mutilatethe battery Released electrolyte is corrosive and may cause damage to the eyes or skin It may be toxic if swallowed 4 Exercisecare in handling batteries in order notto short the batterywith con...

Page 9: ...requires a modular telephone jack and a standard electrical outlet 120v AC The power cord is six feet long make sure there is an electrical outlet within reach of the base The outlet should not be controlled by a wall switch If the switch is ever turned off the phone will not operate 2 Choose and mark the mounting position The mountingscrews shouldscrew into a wooden stud within the wall they will...

Page 10: ...LSE Figure3 gure 1 TONE PULSE SELECTION L Here sa brief guideto the featuresand functions of your VTech VT1900 cordless telephone SET UP Connect telephone line cord to i base unit and telephone jack Plug AC adapter into a standard electrical outlet Set Dial Modeswitch t o m o r unit is factory set Let handset batterieschargefor 24 hours before first use MAKING CALLS Press the P key on the handset ...

Page 11: ...ion is in use on the same line and the VTech VT1900 is in standby mode the L E D will flash Extension in use indication will not function when the handset is out of range VOLUME CONTROLS The handset has a digital volume control The volume controls for the handset are located on the side of the unit Press the A or r keys to increase or decreasethevolume Holdingeither key down will continuously chan...

Page 12: ...inger is capable of four different types of ringertones for each line The followingsectiondetails how to select differentringertypes andhow to turn off the handset ringer DIALYOUR CALL CHANGING RINGER TYPES To program the handsetmustbeOFF 0 a g zJ To select a different ringertype do the NUMBER PRESS PRESSTHE NUMBERS OR SYMBOLS Press 1 for ringer type 1 2 for ringer type 2 3 for ringer type 3 4 for...

Page 13: ...may beafrequently dialedfriend business or emergency number such as 911 There are two ways to dial using QUICK MEM KEY Press Press B QuI MEM The phone number stored in memory location 00 will be automatically dialed STORINGNUMBERSUSINGREDIAL To store the last number dialed into a permanent memory location do the following With the hone in the OFF mode Press The PHONE LED will flash to indicate the...

Page 14: ...aterials to protectyour telephone if you ever need to ship it Avoid water Your telephone can be damaged if it gets wet Do not use the handset outdoors in the rain or handle it with wet hands Do not install your base unit near a sink bathtub or shower Electrical storms Electricalstormscansometimescause power surges harmful to electronic equipment Foryour own safety usecautionwhen usingelectricappli...

Page 15: ...below should solve the problem If you still have difficultyaftertryingthesesuggestions callVTECH Communicationsat 1 800 624 5688 In Canada call VTECH C Electronics at 604 273 5131 When the base unit is unpluggedfrom the powersupply the handsetwill give the Out of Rangewarning beep Plug the base in again and this will stop THE PHONE DOESN T WORK AT ALL Make sure the power cord is plugged in Make su...

Page 16: ...only the materialand workmanship of this product for ONE YEAR from the date of purchase VTECH will repair or replace at our option this product without charge should it fail due to a defect in material or workmanship within that time period This warranty does not apply to loss or damage which is the result of accident misuse or negligence All other warranties expressed implied or statutory includi...

Page 17: ...8 x 62 x 35mm Base 2 1 0 x 1 4 5 1 4 8 WEIGHT Handset 2829 Base 4289 POWER REQUIREMENTS Handset Self contained nickel cad mium rechargeablebattery supply 3 6V nominal 6OOmAh capacity Base 9VDC Q 300mA MEMORY Speed Dial 20 Memory locations 20 digits per location SPECIFICATIONS ARE TYPICAL AND I MAY CHANGE WITHOUT NOTICE I VT1900 Cordless Telephone Wall Mounting Template Use this template when wall ...

Reviews: