HS 2000 System Administrator’s Handbook
Chapter 4. Monitoring System Operation
System Status
75
Dial Mode
The dialing interface specifies which type of network interface protocol
the system uses when a call is made:
Clock Mode
Indicates the source of the system communication clock:
Dial mode
Equipment and protocol used
Direct
External terminal equipment modem control
signaling to connect with external terminal
adapter.
RS-366
External terminal equipment with RS-366 dialing
protocol.
ISDN Internal
Basic rate ISDN. ISDN equipment automatically
supports all the dialing services required to place
the call.
Clock source
Description
Internal
Used when an internal loopback test is performed.
External
The system uses a clock from a network source,
such as a multiplexer or terminal interface