Changing the Main Fuses
The Main fuse is housed in a fuse holder located on the back panel of the TL5.5, and
is rated at 2A Slo Blo (100/120Volt AC) or 1A Slo Blo (220/240 Volt AC) ceramic.
The only fuse that is user serviceable is the Main AC fuse. To change the AC fuse first
ensure the unit is powered off, and disconnect the AC power cord from the unit.
Move the TL5.5 so that you can work with the panel in the back of the chassis.
The type of fitting used for the fuses is called a bayonet fit, which describes the action
needed to remove the fuse cap. Locate the Main fuse holder, and loosen it by inserting
a flat head screwdriver into the slot and turning the screw head approximately one
quarter of a turn in a counter-clockwise direction while pressing inwards. The fuse cap
should spring out from its housing with the fuse held inside the cap. Take the fuse out
and replace it with a new one, and insert the fuse cap back into the holder, pushing it
downward while turning it in the clockwise direction to lock it in place. Use the same
procedure to replace the output stage protection fuses.
WARNING: For continued protection against fire
hazard only replace the fuse with the same type and
rating as was originally specified for the TL5.5. If
you have problems locating the correct fuse contact
your VTL dealer or the VTL factory service department.
TL5.5 SERIES II Preamplifier Owner’s Manual
VTL
44