GRA SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTS
2.
Open the fryer section doors above the filter
tank drawer.
3.
Pull filter drawer out, remove filter tank
assembly and push the tank support arms back
into place under the fryer.
4.
Remove splash guard from base frame.
5.
Disconnect pump motor lead wire connector.
6.
From underneath the fryer:
A.
Disconnect flexible line fittings from pump.
7.
Remove pump motor assembly from fryer.
A.
Remove pipe fittings from the pump and
install on replacement pump.
8.
Reverse procedure to install and check for
proper operation.
FRY TANK ASSEMBLY
1.
Drain shortening from fryer tank.
2.
Disconnect the gas supply line to allow access
to fryer from all sides.
3.
Remove fryer baskets, crumb screen and
basket hanger.
NOTE:
If the fryer is a battery section, remove
grease strip and split the silicone seal between the
fryer section tanks with a utility knife.
4.
On battery fryer sections only, remove bolts
securing the drain pipe flange to the manual
drain valve.
5.
Disconnect temperature probe and drain valve
interlock switch (DVI) connector (6 pin).
F25377 (March 2010)