SECTION 8 - DISASSEMBLY/REASSEMBLY
8.7 DOOR ASSEMBLY/ ADJUSTMENT
TOOLS:
5/32 Allen wrench
Phillips head screwdriver
If the door feels too stiff or too loose when lifting up and
down, a tension adjustment can be made from the outside.
8.7.1:
If door tension is too loose tighten the screw on each
side until the desired tension is reached. If too tight, loosen
screw.
8.7.2:
If door insulation is rubbing against cabinet, loosen
the 2 screws on each side of door.
8.7.3:
Rotate door out from cabinet and tighten 4 screws.
Check to make sure that rope contacts muffle lip when
closed and insulation clears cabinet when lifted.
8.7.4:
If door or door insulation needs replacement,
remove the 4 screws on bottom of door (step 5.7.2) and slide
from slide out assy.
8.7.5:
Remove 2 screws and slide out door insulation
and spring. If door is to be replaced, remove 2 screws
holding handle.
8.7.6:
Replace with new insulation or door by reversing steps
8.7.4 - 8.7.5.
8.7.7:
Set spacing as described in section 8.7.3. Important!
Screws must be torqued to 25-30 in-lbs.
8 – 6