SHUTDOWN OF GRIDDLE
– MSA AND ASA MODELS
1. Turn thermostats to the OFF position to cut off burners.
2. The pilots will remain lit and monitored by the safe ty valve as long as the main gas
supply is on.
SHUTDOWN OF GRIDDLE WITH STANDING PILOT SYSTEM
– AGM MODELS
1. Turn burner control knobs to the OFF position to cut off burners.
2. The pilots will remain lit as long as the main gas supply is o n.
EXTENDED SHUTDOWN
– ALL MODELS
1. Turn the griddle shut-off valve and/or the main gas supply valve to the OFF position.
2. Unplug the griddle electrical supply cord (if applicable).
3. Apply a heavy coat of vegetable oil over the griddle plate to inhibit rust.