MAINTENANCE 

WARNING

: THE GRIDDLE AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, 

CLEANING OR SERVICING THE GRIDDLE. 

 

WARNING

: DISCONNECT THE ELETRICAL POWER TO THE APPLIANCE AND FOLLOW 

LOCKOUT/TAGOUT PROCEDURES. 
 

LUBRICATION 

All valves and thermostats must be checked and lubricated periodically. Check with your 
Service Agency for details. 
 

VENT / FLUE 

Periodically, when the griddle is cool, check the flue and clear any obstructions. 
 

SERVICE AND PARTS INFORMATION 

Contact the Service Agency in your area to obtain service and parts information. For a 
complete listing of Service and Parts depots refer to www.vulcanhart.com or 
www.wolfrange.com. 
 
When calling for service the following information should be available from the appliance 
serial plate: Model Number, Serial Number, Gas Type and Voltage. 

 

ACCESSORIES 

STANDS 

The griddle has an optional 24” high by 30” deep by 24”, 36”, 48”, 60” or 72” wide 
stainless steel stand with casters or flanged legs. The front casters lock, and flanged legs 
may be bolted to the floor. The stand includes a top shelf with marine edges style lip and 
a lower shelf. When mounted on a stand with standard legs and properly leveled, the 
griddle plate cooking surface should be approximately 36” from the floor. 

CUTTING BOARDS & TOWEL BARS 

Refer to the installation instructions provided with the cutting board or towel bar kit.  

  

 

 

 

   

 

 

 

 

 

 

 

 

FRONT GREASE 

STANDARD 

BULLNOSE 

FRONT GREASE  

TOWEL BAR

FRONT GREASE 

CUTTING 

BOARD

REAR GREASE 

STANDARD 

BULLNOSE 

REAR GREASE  

TOWEL BAR 

Summary of Contents for 948RE

Page 1: ...OPERATION MANUAL FOR Heavy Duty Gas Griddles MODEL MLS 924RE ML 135221 00G24 936RE ML 135222 00G36 948RE ML 135223 00G48 960RE ML 135224 00G60 972RE ML 135225 00G72 www vulcanhart com 924RE AGE24 MODE...

Page 2: ...ORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLA...

Page 3: ...s full responsibility for safe delivery upon acceptance of shipment Check for possible shipping damage immediately after unpacking If the griddle is found to be damaged save the packaging material and...

Page 4: ...est edition available from the National Fire Protection Association Batterymarch Park Quincy MA 02269 In Canada 1 Local codes 2 CAN CSA B149 1 Natural Gas Installation latest edition 3 CAN CSA B149 2...

Page 5: ...ddle and its individual shutoff valve must be disconnected from the gas supply piping system When the gas supply pressure is psig 3 45 kPa or less the griddle should be isolated from the gas supply sy...

Page 6: ...ventilated to the outside of the building through a ventilation system installed by qualified personnel From the termination of the flue to the filters of the hood venting system a minimum clearance...

Page 7: ...le OFF then measure the temperature for that zone The temperature should be 350 F 15 F If not continue to Step 4 Step 4a Set knob check Temperature Remove knob Step 4b Adjust temperature dial verify t...

Page 8: ...dure until the griddle has a slick mirror like finish CONTROLS THERMOSTAT Each thermostat controls the gas flow to the burner to bring that area of the griddle plate up to the set temperature Indicato...

Page 9: ...ostats Each 12 section is a separate cooking zone and allows cooking a wide variety of products over a single griddle plate The chart below is a suggested usage of zone cooking When zone cooking it is...

Page 10: ...ry cooking utensil ONCE PER WEEK Clean the griddle surface thoroughly Use a griddle stone screen or Scotch Bright pad on the surface as necessary Rub with the grain of the metal while the griddle is s...

Page 11: ...com When calling for service the following information should be available from the appliance serial plate Model Number Serial Number Gas Type and Voltage ACCESSORIES STANDS The griddle has an option...

Page 12: ...will not stay lit 1 Low gas pressure problem with regulator or system gas pressure Verify or Call for Service 2 Obstructed or wrong size pilot orifice Call for service 3 Gas supply not purged of air C...

Reviews: