SYMPTOMS
POSSIBLE CAUSES
One burner has a delayed ignition; a several
second lapse when the burner actually lights.
1.
Check gas pressure.
2.
Check that burner is properly seated.
3.
Check that burner ignition ports, pilot flash tube and pilot burner
are all aligned.
4.
Gas orifice obstructed, improperly aligned / spaced, or
incorrect.
5.
Check burner shutter adjustment.
6.
Check pilot flame adjustment.
Excessive or low heat.
1.
Gas shut off valve not completely open.
2.
Thermostats need calibrated. See CALIBRATION section.
3.
Thermostat malfunction.
4.
Gas pressure incorrect.
5.
Unit's gas regulator not installed or malfunctioning.
6.
Incorrect gas type.
7.
Gas orifice obstructed or incorrect.
Heat does not come on when the thermostat
is turned on.
1.
Pilot burner not lit.
2.
Griddle shut-off valve not in ON position.
3.
Low gas pressure.
4.
Thermostat malfunction.
Heavy Duty Gas Griddles - TROUBLESHOOTING