ELECTRIC IGNITER (900RX)
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
1.
2.
Push tab to release igniter from frame and pull
out of unit.
Fig. 7
3.
Label and disconnect wires from electric igniter.
4.
Install in reverse order.
BASO SAFETY VALVE
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
Shut off the gas before servicing the
unit and follow lockout / tagout
procedures.
All gas joints disturbed during servicing must be
checked for leaks. Check with a soap and water
solution (bubbles). Do not use an open flame.
1.
2.
Measure distance between manifold pipe and
valve for reassembly later.
NOTE:
Ignition wires must be routed in front of valves
as shown to prevent them from touching hot heat
shield.
Fig. 8
3.
Disconnect all gas lines and thermocouple from
valve.
4.
Remove valve from unit.
5.
Transfer fittings from old valve to new valve. Use
thread sealant on assembly.
6.
Install new valve to same measurement as in
Step 2.
7.
Continue to install in reverse order.
THERMOSTAT VALVE ASSEMBLY
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
Shut off the gas before servicing the
unit and follow lockout / tagout
procedures.
All gas joints disturbed during servicing must be
checked for leaks. Check with a soap and water
solution (bubbles). Do not use an open flame.
1.
2.
Disconnect gas line.
Heavy Duty Gas Griddles - REMOVAL AND REPLACEMENT OF PARTS
Page 7 of 19
F25383 (0219)