GR SERIES GAS FRYERS - TROUBLESHOOTING
F25125 (March 2003)
Page 23 of 24
FRYMATE (DUMP STATION)
WITH OPTIONAL HEATER
SYMPTOM
POSSIBLE CAUSES
No heat.
1.
Unplugged.
2.
Power switch off or inoperative.
3.
Main circuit breaker off or open.
4.
Malfunctioning heat assembly.
KLEENSCREEN FILTERING
SYSTEM
SYMPTOM
POSSIBLE CAUSES
Oil not filtering, pump motor is on.
1.
Filter screen plugged.
2.
Clog in filter system lines.
NOTE:
When all filtered oil is returned to the fry tank and filter
power switch is off, open the filter drawer approximately 1".
Allow the remaining shortening in the line to drain into the filter
tank to prevent possible clogging after the shortening cools and
solidifies. Close the filter drawer when complete.
3.
Shortening below 300
/
F (too thick).
4.
Filter valve switch malfunction.
5.
Filter valve mechanical malfunction.
6.
Pump is inoperative.
Shortening not discarding, pump motor
on.
1.
Filter screen plugged.
2.
Clog in filter system lines.
NOTE:
When all filtered oil is returned to the fry tank and filter
power switch is off, open the filter drawer approximately 1".
Allow the remaining shortening in the line to drain into the filter
tank to prevent possible clogging after the shortening cools and
solidifies. Close the filter drawer when complete.
3.
Shortening below 300
/
F (too thick).
4.
Discard valve switch malfunction.
5.
Discard valve mechanical malfunction.
6.
Discard hose connection not fully engaged.
7.
Pump is inoperative.
Pump motor is not running.
1.
Filter power switch inoperative.
2.
Filter/discard handle not extended.
3.
Filter/discard valve switch malfunction.
4.
Filter relay malfunction.
5.
Pump motor inoperative.