5. From inside the fryer cabinet, follow the thermostat lead wire to the bulb packing nuts in the bottom of the
tank. With a 5/16" wrench remove the thermostat packing nut and with an 11/16" wrench remove the
thermostat bulb holding nut. (Fig.11)
Fig. 11
6. Pull the thermostat bulb from the fryer through the tank bottom. (Fig. 12)
Fig. 12
7.
Install new thermostat by reversing steps 1-6.