Fig. 27
6.
Remove motor from gear reducer.
7.
To install:
A.
With drive key on shaft, install motor to gear
reducer.
B.
Re-connect motor lead wires.
C.
Replace motor cover and control box cover.
8.
Check for proper operation.
GEAR REDUCER - POWER TILTING
OPTION ONLY
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
Shut off the gas before servicing the
unit and follow lockout / tagout
procedures.
All gas joints disturbed during servicing must be
checked for leaks. Check with a soap and water
solution (bubbles). Do not use an open flame.
1.
Place kettle in the fully upright position.
2.
Support kettle from the bottom in some manner
(2x4 etc.). Raise it slightly to take the kettle pivot
shaft weight off gear reducer.
3.
Remove TILT SWITCH (2S) - POWER TILTING
OPTION ONLY leaving the lead wires
connected.
4.
Remove DOWN LIMIT SWITCH (3S) - POWER
TILTING OPTION ONLY leaving the lead wires
connected.
5.
Remove GAS SHUT-OFF VALVE (1SOL) -
TILTING MODELS ONLY.
6.
Remove DC TILT MOTOR - POWER TILTING
OPTION ONLY.
7.
Loosen set screw securing arm to kettle pivot
shaft (keyed).
8.
Remove e-clip securing arm to kettle pivot shaft.
Note orientation and remove arm from kettle
pivot shaft.
NOTE:
If installed, note the number of washers in
front of and behind the arm on the kettle pivot shaft for
re-assembly.
Fig. 28
9.
Remove switch mounting plate screws (8) from
gear reducer and lift plate away from gear
reducer.
K Series Gas Kettles 2/3 Jacketed Stationary and Tilting - REMOVAL AND REPLACEMENT OF PARTS
Page 17 of 48