Kettle Control Area - K Series Tilting Kettles
Blower Speed Control - Switch Settings
PRESSURE SWITCH (1PAS)
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
1.
Open pressure relief valve until reservoir jacket
is completely vented.
2.
Remove CORNER PANEL (TILTING) or SIDE
PANEL (STATIONARY).
3.
Remove pressure switch from tubing.
4.
Reverse procedure to install.
5.
Remove air from reservoir jacket as outlined
under VENTING procedure.
6.
Check for proper operation.
NOTE:
Pressure switch setting is fixed and should not
be adjusted.
Fig. 9
GAS VALVE
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
Shut off the gas before servicing the
unit and follow lockout / tagout
procedures.
All gas joints disturbed during servicing must be
checked for leaks. Check with a soap and water
solution (bubbles). Do not use an open flame.
1.
Remove CORNER & REAR PANELS
(TILTING) or SIDE & REAR PANELS
(STATIONARY).
2.
Remove electrical connector from gas valve.
3.
Disconnect gas line from gas valve.
4.
Remove gas valve from blower.
K Series Gas Kettles 2/3 Jacketed Stationary and Tilting - REMOVAL AND REPLACEMENT OF PARTS
F45461 Rev. B (1117)
Page 10 of 48