WIRED POWER PAL TROUBLESHOOTING SECTION
The power LED on the PDC circuit board does not come on
.
•
The PDC is not getting power. Be sure that the power and ground
wires are connected properly.
•
Using a DC test lamp, check that there is power applied to the BATT
terminal of the PDC.
•
Check with a voltage meter the power applied is 12 volts.
•
Check for a tight, metal to metal chassis ground.
There is no green light in the upper right hand corner of my wired keypad
.
•
Make sure the coiled cord is properly inserted into the jack on the PDC
circuit board.
•
Check the ‘wired/wireless’ switch; switch to the ‘wired’ position.
Some or no outputs function when I press a button on the remote
.
•
Check for the green indicator light on the keypad.
•
Make sure all output wires are properly connected to their destination.
•
Check suspected output wire for a secure connection at the output
stab of the PDC circuit board.
•
Short or overload condition. While pressing the position on the
keypad, look at the indicator LED on the PDC board that is associated
with the suspected function. If the RED LED is lit, there is an overload
condition or a short circuit in the output wiring. Correct the condition.
•
If only the green LED is lit, there is an open connection somewhere
between the output of the circuit board and the solenoid valve. Check
your wiring.
•
If no LED’s light up, contact Power Up Products for further assistance.
I press a button and the wrong function comes on
.
•
Check that the output wires are connected to the correct output
position.
•
Following the wiring scheme on page 5.
If you require further assistance, contact Power Up Products Technical
Assistance. Monday through Friday from 8:00 to 4:00 PST. (775) 336-2400