Fig. 16
5.
Install compression fitting elbows on
replacement gas valve then reverse procedure to
install the valve.
Clean pipe threads and apply thread
sealant that is suitable for use with propane gases.
6.
Perform GAS MANIFOLD PRESSURE
ADJUSTMENT.
INFRARED BURNER
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas before servicing the
unit.
NOTE:
Infrared burner is removed through the front
of griddle.
1.
2.
Remove CONTROL DEFLECTOR (HEAT
SHIELD).
3.
Perform THERMOCOUPLE (INFRARED
BURNER) removal procedure to access the
thermocouple shield and remove it. The shield
must be removed for burner removal clearance
but the thermocouple can remain installed.
4.
Disconnect compression fitting from pilot orifice
fitting at pilot venturi inlet on burner.
5.
Disconnect compression fitting from burner
orifice fitting at burner venturi inlet.
Two wrenches may be required to
disconnect compression fittings if the orifice fittings
begin to turn or damage to the flexible tubing may
occur. Use (1) wrench on compression fitting and (1)
wrench on the orifice fitting.
Fig. 17
6.
Disconnect the pilot and burner flexible tubing
from gas valve.
7.
Remove screws (2) securing front of burner to
frame.
Fig. 18
8.
Lift burner up at the front and pull out to remove
from griddle.
A.
Remove pilot orifice fitting and burner orifice
fitting from burner. Install on replacement
burner.
Clean pipe threads and apply thread
sealant that is suitable for use with propane gases.
9.
Reverse procedure to install replacement burner.
10. Check for proper operation.
VCCG Series Heavy Duty Gas Griddle - REMOVAL AND REPLACEMENT OF PARTS
F45533 (1014)
Page 10 of 26