REMOVAL AND REPLACEMENT OF PARTS
FRONT PANEL
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
The front panel holds the temperature controllers,
thermostat cycle lights and lighted power switch.
1.
Remove four screws securing the front panel to
frame.
Fig. 1
2.
Lay front panel face down in front of the unit while
servicing. Pull the drawer out to support the panel
as necessary.
NOTE:
Griddles that are 60" and 72" wide have 2
grease drawers.
3.
Reverse procedure to install.
BACK PANEL
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas before servicing the
unit.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
NOTE:
Remove the back panel when servicing a
burner, temperature probe, pilot burner; or to remove
excessive grease build up from the flue area.
1.
Disconnect gas supply at griddle.
2.
Remove all screws from rear of griddle securing
the back panel.
Fig. 2
3.
Reverse procedure to install.
CONTROL DEFLECTOR (HEAT
SHIELD)
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1.
2.
Remove control deflector (heat shield) from
griddle frame. The number of mounting screws
installed depends on griddle width. After screws
are removed, lift the control deflector and rotate
forward to remove from griddle.
Fig. 3
3.
Reverse procedure to install and check for proper
operation.
VCCG Series Heavy Duty Gas Griddle - REMOVAL AND REPLACEMENT OF PARTS
Page 5 of 26
F45533 (1014)