VSX SERIES STEAMER - TROUBLESHOOTING
Form 24627 (December 98)
Printed in U.S.A.
GAS MODELS ONLY
SYMPTOM
POSSIBLE CAUSES
Burner won’t light.
1.
Gas not on.
2.
Ignition control module reset switch in the OFF position or
malfunctioning.
3.
Ignition module not receiving power. Check ignition module
transformer for 24VAC output to module on automatic ignition
systems.
4.
Unit not properly grounded and/or polarity of incoming power is
incorrect on automatic ignition systems.
5.
Low incoming gas pressure. See “MANIFOLD PRESSURE
ADJUSTMENT” in “SERVICE PROCEDURES”.
6.
Ignition module malfunction.
7.
Gas combination control valve malfunction.
8.
Boiler not filling. Check fill solenoid for power, clogging or
malfunction.
9.
Water level control malfunction.
10.
Water too ”pure” for probes to properly conduct electricity.
11.
High limit thermostat open (if equipped).
12.
High limit pressure switch open.
13.
Cycling pressure switch open or set too high. Unit is cycling on
high limit. See “PRESSURE SWITCHES (GAS AND ELECTRIC
MODELS) in SERVICE PROCEDURES”.
Burner won’t stay lit.
1.
Gas pressure low. See “MANIFOLD PRESSURE ADJUSTMENT”
in “SERVICE PROCEDURES”.
2.
Ignition module malfunction.
3.
Check gas orifice for obstruction.
Pilot not lit or goes out.
1.
Gas not on.
2.
Low incoming gas pressure.
3.
Check thermopile millivolts.
4.
Pilot going out due to drafts, excess steam from drain or unit not
level. Improper venting can direct the pilot flame away from
thermopile or flame sensor.
5.
Pilot not adjusted correctly. See “PILOT, THERMOCOUPLE OR
MAIN BURNERS” in “SERVICE PROCEDURES”.
6.
Burners ignite too violently. Check gas pressure to the unit. See
“MANIFOLD PRESSURE ADJUSTMENT” in “SERVICE
PROCEDURES”.
7.
If auto ignition and no sparking - ignition module malfunction.
8.
Wrong pilot assembly used.
Spark Ignitor not sparking.
1.
Incorrect spark gap setting. See “AUTOMATIC IGNITION
SYSTEMS” in “SERVICE PROCEDURES”.
2.
Poor ground between pilot bracket and burner.
3.
Loose, broken or damaged lead wires (including ground) from
ignition module to ignitor.
4.
Ignitor boot on ignition cable loose, damaged or missing causing
excessive ignition voltage leakage.
5.
Ceramic flame rod insulator on ignitor cracked or damaged from
extreme heat.
6.
Ignition module not receiving power.
7.
Ignition module malfunction.
Summary of Contents for VSX24D
Page 12: ...VSX SERIES STEAMERS COMPONENT FUNCTION AND LOCATION Page 12 of 80 ...
Page 13: ...VSX SERIES STEAMERS COMPONENT FUNCTION AND LOCATION Page 13 of 80 ...
Page 40: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 40 of 80 PAGE PURPOSELY LEFT BLANK ...
Page 42: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 42 of 80 Electronic Ignition Standard Controls ...
Page 43: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 43 of 80 Manual Ignition CSD 1 Code Controls ...
Page 44: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 44 of 80 Electronic Ignition CSD 1 Code Controls ...
Page 45: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 45 of 80 ...
Page 47: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 47 of 80 ...
Page 48: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 48 of 80 Electronic Ignition Standard Controls ...
Page 49: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 49 of 80 ...
Page 50: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 50 of 80 Manual Ignition CSD 1 Code Controls ...
Page 51: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 51 of 80 ...
Page 52: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 52 of 80 Electronic Ignition CSD 1 Code Controls ...
Page 53: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 53 of 80 ...
Page 55: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 55 of 80 Auto Blowdown Cal Code Controls ...
Page 56: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 56 of 80 Auto Blowdown Standard Controls ...
Page 57: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 57 of 80 Auto Blowdown Cal Code Controls ...
Page 59: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 59 of 80 ...
Page 60: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 60 of 80 Auto Blowdown Cal Code Controls ...
Page 61: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 61 of 80 ...
Page 62: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 62 of 80 Auto Blowdown Standard Controls ...
Page 63: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 63 of 80 ...
Page 65: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 65 of 80 ...
Page 67: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 67 of 80 ...
Page 69: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 69 of 80 ...
Page 72: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 72 of 80 3 Phase 4 Wire Older Models ...
Page 75: ...VSX SERIES STEAMER ELECTRICAL OPERATION Page 75 of 80 Auto Blowdown ...