VXI Technology, Inc.
18
CT-310A Introduction
P
OWER
S
PECIFICATIONS
U
SEABLE
P
OWER
500 W up to 40°C
Linearly derated to 300 W at 55°C
DC
S
UPPLY
V
OLTAGE
Voltage
Peak Current
(I
MP
)
Dynamic Current (I
MD
)
+5
V 40
A
5 A
-5.2
V 10
A
5 A
-2
V 8
A
2 A
+12
V 8
A
2 A
-12
V 4
A
2 A
+24
V 4
A
2 A
-24
V 4
A
2 A
O
UTPUT
V
OLTAGE
Voltage
Allowed Variation
Ripple/Noise
DC Load
Induced Ripple
Noise
+5 V
+0.25 V / -0.125 V
50 mV
50 mV
-5.2 V
-0.26 V / +0.125 V
50 mV
50 mV
-2 V
-0.10 V / +0.72 V
50 mV
50 mV
+12 V
+0.60 V / +0.36 V
50 mV
50 mV
-12 V
-0.60 V / +0.36 V
50 mV
50 mV
+24 V
+1.20 V / -0.72 V
150 mV
150 mV
-24 V
-1.20 V / +0.74 V
150 mV
150 mV
P
OWER
I
NPUT
Input Voltage / Freq.
Nominal
ac
Inrush current
Input power
Input leakage
Input harmonics
Fuse
100 V ac – 240 V ac, 50 Hz/60 Hz
< 40 A (cold start)
10 A maximum
< 1.24 MA @ 264 V ac, 53 Hz
Meets EN61000-3-2
Internal (not user accessible)
P
OWER
S
UPPLIES
UL, CSA, TUV approved, CE marked
Shout circuit, over-voltage, reverse voltage and thermal shutdown protection