18
Extension leads should be heavy duty with at least 1mm, of appropriate current rating
and in any case not less than 1mm cross-section of conductor and must incorporate an
earthing conductor to ensure that there is no voltage difference between the generator
set and any equipment powered by the generator.
The electrical continuity of the ‘earthing’ core should be checked periodically from pin to
socket to ensure continued electrical safety. Some electrical appliances, e.g. portable
drills, are marked or ‘double insulated’, in which case there should not be an earthing
conductor in its mains lead (even though it may have a three-pin plug).
!
WARNING
Use of under sized extension cords can cause
electric shock, fire, or damage to connected
devices. All extension and appliance cords
must be in good condition and not worn, bare,
frayed, or otherwise damaged.
Use of damaged electric cords can cause
electric shock or fire. Note: If an extension
cord becomes hot to the touch, it is overloaded
or damaged and must be replaced. Vyking
Force is NOT responsible for damage or injury
resulting from customer use of inadequate
extension cords.
Select a suitable site
Before using the generator, you must select a suitable OUTDOOR location for
installation and operation that meets the following criteria:
Dry, level surface
The generator should be positioned on a dry, firm, level surface. Ensure that the
generator sits level and will not slide or shift during operation. If applicable, block the
generator’s wheels to prevent sliding and shifting.
!
WARNING
You must choose a suitable site for operating
your generator to avoid equipment damage
and/or injury and possible death from carbon
monoxide poisoning, electric shock, or fire.