Store the generator in a location that is clean, dry, away from sources of heat, open
flames, sparks, or pilot lights and is not subject to extreme high or low temperatures.
Residual fuel in the tank could ignite even if the generator’s fuel tank is empty.
Note: Do not store with battery charger always connected. Batteries that are over-
charged can boil dry and produce excessive amounts of hydrogen, an explosive gas.
Prevent accidental starting
Remove spark plug(s) in order to ensure the generator cannot be started accidentally in
a storage location or by untrained persons.
Operate engine regularly
The generator should be operated regularly to maintain the condition of internal parts.
At least every four weeks, start the engine and let it run for 10 to 15 minutes with a small
load plugged in, such as a lamp or fan.
Monthly operation of the generator will dry out any moisture that has accumulated in the
windings which if left can cause corrosion. It will also ensure that the unit is operating
properly should it be needed in an emergency.
Perform regular maintenance
Perform periodic maintenance as directed in this manual to keep the generator in safe
working condition.
Prepare engine for long term storage
If you will not be able to operate the generator regularly, you must prepare the engine for
long term storage to prevent gum deposits from forming and causing malfunction of the
engine.
Prepare generator for long term storage by removing all fuel from the tank and
carburettor OR adding fuel stabilizer to the petrol (following manufacturer’s instructions)
Fuel stabilizer steps:
1. Ensure tank is full.
2. Add fuel stabilizer to fuel tank.
3. Run engine at least 10 minutes after adding stabilizer to allow it to enter the fuel
system.
4. Shut off engine.
5. Disconnect spark plug wire and remove spark plug.
6. Add one teaspoon oil through spark plug opening.
7. Place rag over spark plug hole and turn starter (or pull the recoil) a few times to
lubricate the combustion chamber. This will distribute the oil and protect the cylinder
wall from corrosion during storage.