40
9. Fill crankcase with oil following the steps outlined in Adding Engine Oil on page 38.
10. Dispose of used engine oil properly.
NOTICE
Never dispose of used engine oil by
dumping the oil into a sewer, on the ground,
or into groundwater or waterways. Always
be environmentally responsible. Follow the
guidelines of the EPA or other governmental
agencies for proper disposal of hazardous
materials. Consult local authorities or
reclamation facility.
Air filter maintenance
!
WARNING
Never use petrol or other flammable
solvents to clean the air filter. Use only
household detergent soap to clean the air
filter.
Cleaning the Air Filter
The air filter must be cleaned after every 50 hours of use or 3 months (frequency should
be increased if inverter is operated in a dusty environment).
1. Turn off the inverter and let it cool for several minutes if running.
2. Remove the engine service panel to gain access to the air filter.
3. Unscrew the air cleaner cover and tip the coverdown (see Figure 14).