53
2.5kVA Inverter Generator VF2200IG
Engine will not start or remain
running while trying to start.
1. Inverter is out of petrol.
1. Add petrol to the inverter.
2. Fuel flow is obstructed.
2. Inspect and clean fuel
delivery passages.
3. Dirty air filter
3. Check and clean the air
filter.
4. Low oil level shutdown
switch is preventing
the unit from starting.
4. Check oil level and add oil if
necessary.
5. Spark plug boot is not fully
engaged with
the spark plug tip.
5. Firmly push down on the
spark plug boot to
ensure the boot is fully
engaged.
6. Spark plug is faulty.
6. Remove and check the
spark plug. Replace
if faulty.
7. Dirty/plugged spark arrestor 7. Check and clean the spark
arrestor.
8. Stale fuel
8. Drain fuel and replace with
fresh fuel.
Inverter suddenly
stops running.
1. Inverter is out of fuel.
1. Check fuel level. Add fuel if
necessary.
2. The low oil shut down
switch has stopped
the engine.
2. Check oil level and add oil if
necessary (see
page 18).
3. Too much load
3. Restart the inverter and
reduce the load.
Engine runs
erratic; does not hold a
steady RPM.
1. Choke was left in the
CHOKE position.
1. Move choke to the RUN
position
2. Dirty air filter
2. Clean the air filter.
3. Applied loads maybe cycling
on and off
3. As applied loads cycle,
changes in engine
speed may occur; this is a
normal condition.