Page 29 of 48
PAM-199-P
5 Parameter description
5.1
FUNCTION (Function mode)
Command
Parameters
Unit
Group
FUNCTION
FUNCTION X
x= 195|196|197
-
STD
195
196
197
The general function of the module will be defined by this command.
195: Functionality for directional valves with two solenoids and analogue input signals
196: Functionality for two pressure/throttle valves with analogue input signals
197: Functionality for directional, pressure and throttle valves with pre-programmed values, selectable by
digital inputs.
CAUTION:
After changing this parameter the ID-button has to be pressed in order to rebuild the pa-
rameter table and a SAVE has to be conducted.
5.2
LG (Changing the language for the help texts)
Command
Parameters
Unit
Group
FUNCTION
LG
X
x= DE|EN
-
STD
195
196
197
Either German or English can be selected for the help texts in the WPC-300 program.
CAUTION:
After changing the language settings the parameter list has to be updated by pressing the
speed bu
tton “ID”.