5.5
CCMODE (Activation of the characteristic linearization)
Command
Parameters
Unit
Group
FUNCTION
CCMODE
X
x= ON|OFF
-
EXP
195
196
This command will be used for activation or deactivation of the characteristics linearization (CC, CCA and
CCB). Through deactivating this parameter a simple and quick estimation of the linearization is possible.
5.6
SOLENOIDS (One or two solenoids)
Command
Parameters
Unit
Group
FUNCTION
SOLENOIDS X
x= 1|2
-
STD
197
This parameter allows you to adapt the amplifier to valves with one solenoid (e.g. pressure valves) or to such
with two solenoids (directional valves).
5.7
PIN:5 (Choice of the additional function of PIN 5)
Command
Parameters
Unit
Group
FUNCTION
PIN:5
x
x= RDY | SOL
-
EXP
195
197
This parameter defines the functionality of digital input PIN:6
RDY:
Standard READY output.
SOL:
Detection of the activated solenoid.
1 = solenoid is active
0 = solenoid A is active.