Page 34 of 48
PAM-199-P
5.12
POL (Output polarity)
Command
Parameters
Unit
Group
FUNCTION
POL:I
X
i= A|B
x= +|-
-
STD
196
POL
X
x= +|-
-
STD
195
Valves with one solenoid:
This command allows a switch over of the output signal direction (after the MIN-MAX function).
Example:
POL:A
+
Input signal 0… 100 %, nominal output current 0… 100 %.
POL:A
-
Input signal 0… 100 % nominal output current 100… 0 %.
Directional valves:
This command allows a switch over of the output polarity.
5.13
AINA (Current- / Voltage input)
5.14
AINB (Current- / Voltage input)
Command
Parameters
Unit
Group
FUNCTION
AINA X
AINB X
x=V|C
-
STD
195
196
By the use of this command the type of input signal may be chosen between voltage (0...10 V or +/- 10 V) or
current (4…20mA). If current is chosen, the shunt will be activated automatically.