Page 13 of 21
X2 – Pin test of pins 10–12
Type:
Test of the functions of pins 10–12 of the ISO 12098 cable
Step 1:
Connect the ISO 12098 cable to the X2 connection of the W.EASY Trailer Power case.
Steps 2 + 3:
Connect the ISO 12098 cable to the corresponding connection on the trailer.
Step 4:
Use the "Power" rocker switch to switch on the case.
Step 6:
Use the "Mode" rocker switch to activate mode 3 (see details on the display).
Step 7:
Now use the remote control or the +/- rocker switch to select the required PIN.
Currently selected PIN is shown on the display
Now actuate the selected PIN with the required signal:
o
24V – level:
Rocker switch on case/up button on remote control
o
0V/earth
Rocker switch on case/down button on remote control
Available aids for checking in W.EASY Trailer Power:
o
Measurement and display of the voltage and current at the current line (see
display)
Use the remote control or the +/- rocker switch to switch between the
individual lines
Current measurement, voltage measurement and indication on the display
The equipment displays the voltage measured and the present current flow
for each controlled PIN.
Note:
The individual PINs are selected using the remote control or the +/- button
on the case.
Switching sequence
Sequence PIN
Meaning
Icon
8
X2.10
Freely assignable PIN
9
X2.11
Freely assignable PIN
10
X2.12
Freely assignable PIN