background image

 

WABRO s. c. 

ul. Arki Bożka 2A

, 41-910 Bytom 

NIP: PL6263032331  |  Regon: 381911373 

 

 

 

Wabrotech.pl 

 

 

1.

 

INTENDED USE AND CHARACTERISTICS 

APPLICATION

 

 

Magnetic grippers of the PML series are magnetic circuits made using permanent magnets. 

They are used to lift and carry heavy elements made of iron and steel        magnetic. 
 

These devices do not require any external or internal power supply. Turning on and 

disconnection of the magnetic field occurs as a result of moving the manual lever. A magnetic field of 
grippers is produced by the latest generation magnets. Thanks to its small size and relatively low 
weight, they are very comfortable and easy to use.  
 

They are used in steel depots, factories, warehouses, workshops, docks and everywhere where 

they can be helpful in handling sheets, plates and other large steel elements both flat and cylindrical. 
 

 

2.

 

CONSTRUCTION AND PARAMETERS OF PML SERIES GRIPPERS 

 

 

 

Solid and durable construction with a very easy to use switching mechanism ON/OFF. The 

mechanism is equipped with a safety lock - prevents accidental switching to the OFF position.  
 

The contact surface of the magnet is in the form of elongated fields shaped so as to ensure 

good contact with both flat and cylindrical objects. By using the strongest Currently neodymium 
magnets magnetic grippers have enormous lifting power in comparison with their own dimensions and 
weight.  
 

Changing the switch lever when the gripper is already placed on the one to be moved parts, it 

is very comfortable, simple and does not require much force. 
 

 

 

 

TECHNICAL SPECIFICATIONS

 

Model 

Nominal capacity

KG

 

Dimensions

mm

 

Payload (KG) 

Libra 
(KG) 

Element 

flat 

Element 

cylindrical 

PML - 1 

100 

30 

135 

63 

75 

160 

250 

PML – 2 

200 

60 

170 

67 

80 

160 

500 

3,9 

PML – 4 

400 

120 

180 

92 

94 

215 

1000 

9,3 

PML – 6 

600 

180 

240 

120 

115 

240 

1500 

19,9 

PML – 10 

1000 

300 

300 

136 

138 

270 

2500 

32,3 

 

 
 
 
 

 

 
 

Summary of Contents for PLM-6

Page 1: ......

Page 2: ...ZNEGO Z MAGNESEM TRWA YM 4 5 SCHEMAT MONTA U UCHWYTU MAGNETYCZNEGO 5 6 KONSERWACJA I BEZPIECZE STWO 6 Prosz przeczyta i zachowa t instrukcj Przeczytaj uwa nie przed przyst pieniem do monta u instalacj...

Page 3: ...ement w zar wno p askich jak i walcowych 2 BUDOWA I PARAMETRY CHWYTAK W SERII PML Solidna i wytrzyma a konstrukcja z bardzo atwym w obs udze mechanizmem prze czaj cym ON OFF Mechanizm wyposa ony w blo...

Page 4: ...etrznej mi dzy adunkiem a magnesem Ten efekt odklejania si znacznie zmniejsza ud wig magnesu W przypadku podnoszenia p yt gdy nast puje opadanie magnesy o kszta cie prostok tnym nale y umie ci tak aby...

Page 5: ...krzyw procentow SZCZELINA POWIETRZNA W odniesieniu do jako ci powierzchni je eli chropowato powierzchni jest mniejsza ni 6 3 um mi dzy chwytakiem a detalem nie mo e powsta adna znacz ca szczelina pow...

Page 6: ...ezpiecze stwa podno nika FX MX 16 um 125 Stal niskow glowa 100 6 3 um 100 Wewn trz stali niskow glowej 95 12 6 um 90 Stal wysokow glowa 90 80 Stal niskostopowa 75 eliwo 50 TX FX MX ocena ud wigu kg Pr...

Page 7: ...i pewnie si blokuje 5 Zabronione jest obracanie d wigni chwytaka bez styczno ci detalu elaznego ze spodem powierzchni stykow chwytaka 6 Konserwacja powinna by przeprowadzana wy cznie przez upowa nion...

Page 8: ...NG GRAPPLE CAPACITY MAGNETIC WITH PERMANENT MAGNET 10 5 ASSEMBLY SCHEME OF THE MAGNETIC HOLDER 11 Please read and keep this manual Please read carefully before attempting to assemble install operateor...

Page 9: ...at and cylindrical 2 CONSTRUCTION AND PARAMETERS OF PML SERIES GRIPPERS Solid and durable construction with a very easy to use switching mechanism ON OFF The mechanism is equipped with a safety lock p...

Page 10: ...eate an air gap between the load and the magnet This peeling effect greatly reduces the magnet s lifting capacity In the case of lifting plates when falling rectangular magnets should be placed so tha...

Page 11: ...ndition according to the AIR GAP percentage curve should also be taken care of With regard to surface quality if the surface roughness is less than 6 3 m no significant air gap can develop between the...

Page 12: ...he safety range of the lift TX FX MX ocean capacity kg Example Steel element T8 FI M3 1000Kg LS1 1000 65 125 90 1000 731Kg 5 ASSEMBLY SCHEME OF THE MAGNETIC HOLDER FX MX 16um 125 Low carbon steel 100...

Page 13: ...and locks securely 6 5 It is forbidden to rotate the gripper lever without contact of the iron detail with the bottom gripper contact surface 6 6 Maintenance should only be carried out by authorized t...

Page 14: ...TMAGNET 16 5 MONTAGESCHEMA DES MAGNETHALTERS 17 Bitte lesen Sie dieses Handbuch und bewahren Sie es auf Bitte lesen Sie diese sorgf ltig durch bevor Sie versuchen das Produkt zusammenzubauen zu instal...

Page 15: ...isch 2 KONSTRUKTION UND PARAMETER DER GREIFER DER PML SERIE Solide und langlebige Konstruktion mit einem sehr einfach zu bedienenden Schaltmechanismus AN AUS Der Mechanismus ist mit einer Sicherheitsv...

Page 16: ...neten entstehen Dieser Peeling Effekt verringert die Tragf higkeit des Magneten erheblich Beim Heben von herabfallenden Platten sollten rechteckige Magnete so platziert werden dass die L nge des Magne...

Page 17: ...anhand der Prozentkurve AIR GAP geachtet werden Was die Oberfl chenqualit t betrifft so kann bei einer Oberfl chenrauheit von weniger als 6 3 m kein nennenswerter Luftspalt zwischen Greifer und Werks...

Page 18: ...des Aufzugs FX MX 16um 125 Kohlenstoffarmen Stahl 100 6 3um 100 Im Inneren des Stahls wenig Kohlenstoff 95 12 6um 90 Stahl mit hohem Kohlenstoffgehalt 90 80 Niedriglegierter Stahl 75 Gusseisen 50 TX F...

Page 19: ...st und sicher einrastet 5 Es ist verboten den Greiferhebel zu drehen ohne dass das Eisenteil den Boden Boden ber hrt Kontaktfl che des Greifers 6 Die Wartung sollte nur von autorisiertem technischem P...

Page 20: ...nione powy ej urz dzenia zosta y wyprodukowane zgodnie z nast puj cymi Dyrektywami Europejskimi 2006 42 EC MD Dyrektywa Maszynowa and harmonised with these directives standards oraz zharmonizowanymi z...