54
www.nieaf-smitt.com
5.8 Continuity check
WARNING: To avoid electric shock, never
measure continuity on circuits or wires that
have voltage on them
1. Set the function switch to the
green
Ω CAP
position
2. Insert the black lead banana plug into the negative
COM jack
3. Insert the red test lead banana plug into the positive
Ω jack
4. Press the MODE button to indicate ‘ ‘ and ‘Ω’ on
the display
5. Touch the test probe tips to the circuit or wire you
wish to check
6. If the resistance is less than approximately 35 Ω,
the audible signal will sound. If the circuit is open,
the display will indicate ‘OL’