background image

 

08/10/14 

32II470e.B 

2 of 5 

III. INTRODUCTION 

 

The purpose of this document is to outline the step by step procedure for the installation of Kit #55914 for PCB 
RI55664 and Extension Harness RI55913 (if needed) for the S/K Series Lifts.  Follow all safety precautions before 
attempting to perform installation or maintenance of the S/K Series Lift. Remove power to vehicle and/or turn off 
ignition.  Remove the power cable from the S/K Series Lift. 

 

A.  REMOVAL OF FACTORY PCB 

Note:

 The Pump assembly may or may not need to be removed depending on the lift configuration (Left hand or Right 

hand side) and location of PCB.  If removal is unnecessary, skip to step 3 below. 

1.  Remove the pump cover, making sure to unplug the warning light if installed, and set aside. 

2.  Unbolt the pump assembly; pull and tie away from the lift for optimum working area.  Removal of the hydraulic 

lines and/or electrical connections may be necessary. 

3. 

Important!

 Locate factory PCB.  Remove electrical connections from PCB, making sure to make a note or 

mark the connections for terminals T1-T4 for ease of identification and installation later. 

4.  Remove the factory PCB assembly from the lift. 

5.  Remove the factory PCB from the PCB mounting plate. 

6.  Install PCB RI55664 onto the PCB mounting plate. 

 

IV. 

INSTALLATION OF KIT #55914 

A.  INSTALLATION OF PCB ASSEMBLY 

Note:

 PCB RI55664 is sent configured from the manufacturer with jumpers in the following locations; J9, J14. 

1.  Configure the jumpers on PCB RI55664 for the lift application. Remove jumpers as needed.  

Refer to Figure 1. 

 

If Replacing 

Leave 

Remove

33461 J9, 

J14 

N/A 

33057 J14 

J9 

55809 J9 

J14 

47388 J9 

J14 

55664 J9 

J14 

FIGURE 1: PCB RI55664 JUMPER CONFIGURATION MATRIX 

 

2.  Install the PCB assembly on the lift.  

3.  Install TWS sensor sets to PCB, ensuring TWS sensors sets are properly connected. Refer to Figures 2-3.

 

 

TWS Sensor Set  #

Sensor Set Location

1 J4, 

J5 

2 J6, 

J7 

3 (If applicable) 

J13, J14 

FIGURE 2:  PCB RI55664 TWS SENSOR SET LOCATIONS 

 

Summary of Contents for Ricon 55914

Page 1: ...ce of an individual capable of giving aid Give immediate attention to all injuries and administer first aid or seek medical attention as necessary Protective eye shields and clothing should be worn during maintenance repair and adjustment of the R2000 Power Seat Base Work in a properly ventilated area Check for hidden obstructions before drilling and cutting Avoid interference with wiring fuel tan...

Page 2: ...r electrical connections may be necessary 3 Important Locate factory PCB Remove electrical connections from PCB making sure to make a note or mark the connections for terminals T1 T4 for ease of identification and installation later 4 Remove the factory PCB assembly from the lift 5 Remove the factory PCB from the PCB mounting plate 6 Install PCB RI55664 onto the PCB mounting plate IV INSTALLATION ...

Page 3: ...B 3 of 5 FIGURE 3 TWS SENSOR SET IDENTIFICATION 4 Install Terminal T1 T4 in the correct PCB location Refer to Figures 4 5 FIGURE 4 PREVIOUS TERMINAL ORIENTATION LEFT RIGHT SET 1 SET 2 SET 3 If Applicable TX RED RX GREEN ...

Page 4: ...o be extended If upon installing PCB assembly RI55664 the harness does not reach connector J2 proceed with section B Otherwise continue to section C 1 Locate harness connector that mates with J2 and cut wires at end of connector Refer to Figures 6A 6B Strip the wire ends as necessary FIGURES 6A 6B REMOVAL OF HARNESS CONNECTOR J2 2 Splice in extension harness RI55913 Connect the extended harness to...

Page 5: ...S EXTENSION INSTALLATION REFERENCE ONLY C FINAL INSTALLATION 1 Re install the pump assembly to the lift reconnect hydraulic lines and electrical connections if applicable 2 Re install the pump cover making sure to plug the warning light if installed ...