08/10/14 

32II470e.B 

5 of 5 

  

 

FIGURES 7A/7B: HARNESS EXTENSION INSTALLATION (REFERENCE ONLY) 

 

 

 

C.   FINAL INSTALLATION 

1.  Re-install the pump assembly to the lift; reconnect hydraulic lines and electrical connections if applicable. 

2.  Re-install the pump cover, making sure to plug the warning light if installed. 

 

 

Summary of Contents for Ricon 55914

Page 1: ...ce of an individual capable of giving aid Give immediate attention to all injuries and administer first aid or seek medical attention as necessary Protective eye shields and clothing should be worn during maintenance repair and adjustment of the R2000 Power Seat Base Work in a properly ventilated area Check for hidden obstructions before drilling and cutting Avoid interference with wiring fuel tan...

Page 2: ...r electrical connections may be necessary 3 Important Locate factory PCB Remove electrical connections from PCB making sure to make a note or mark the connections for terminals T1 T4 for ease of identification and installation later 4 Remove the factory PCB assembly from the lift 5 Remove the factory PCB from the PCB mounting plate 6 Install PCB RI55664 onto the PCB mounting plate IV INSTALLATION ...

Page 3: ...B 3 of 5 FIGURE 3 TWS SENSOR SET IDENTIFICATION 4 Install Terminal T1 T4 in the correct PCB location Refer to Figures 4 5 FIGURE 4 PREVIOUS TERMINAL ORIENTATION LEFT RIGHT SET 1 SET 2 SET 3 If Applicable TX RED RX GREEN ...

Page 4: ...o be extended If upon installing PCB assembly RI55664 the harness does not reach connector J2 proceed with section B Otherwise continue to section C 1 Locate harness connector that mates with J2 and cut wires at end of connector Refer to Figures 6A 6B Strip the wire ends as necessary FIGURES 6A 6B REMOVAL OF HARNESS CONNECTOR J2 2 Splice in extension harness RI55913 Connect the extended harness to...

Page 5: ...S EXTENSION INSTALLATION REFERENCE ONLY C FINAL INSTALLATION 1 Re install the pump assembly to the lift reconnect hydraulic lines and electrical connections if applicable 2 Re install the pump cover making sure to plug the warning light if installed ...