3 - 7
MAINTENANCE
MAY 2020
32DFRE02.C
FR2E-SERIES SERVICE MANUAL
E.
WIRING DIAGRAM
RSM0068700
Y B R
NC
NO
COM
RAMP
DIRECTION
SW1
Y B R
NC
NO
COM
DEPLOY
SHUNT
SW6
Y B R
NC
NO
COM
STOW
SHUNT
SW3
Y B R
NC
NO
COM
RAMP
STOWED
SW2
Y B R
NC
NO
COM
DEPLOY
CUTOFF
SW5
Y B R
NC
NO
COM
STOW
CUTOFF
SW4
1
2
3
4
5
6
2
1
1
2
3
4
5
6
1
2
3
4
5
6
K1
12V/24V
K3
K2
K4
12V/24V
12V/24V
OU
T-
3
OU
T-
2
OU
T-
1
IN
+3
IN
+2
IN
+1
OU
T
GN
D
5V
IN
5A
CUR
CUR
5V REG
12V REG
12V/24V
R1
R2
12V/24V
1: SUPPLY GND
5: DC
40: RAMP STOWED-IN
39: STOW-OUT
38: RAMP STOWED-OUT
24: TEST
23: DC
55: COUNTER-OUT
54: DEPLOY-OUT
41: STOW-IN
52: DEPLOY-IN
2-GND
1-12/24V (PULSED)
CURRENT
TRANSDUCER
FR2E RAMP ASSY
3A
COUNTER CONN
(COUNTER)
1
2
1
2
1
1
2
3
4
5
6
7
8
9 10 11 12
2
3
4
5
6
7
8
9 10 11 12
N/C N/C N/C
N/C N/C N/C
(CONTROLLER)
BLACK (#14)
RED (#14)
RED (#12)
CONFIG CONN
N/C
N/C
BLACK (#12)
BLACK (#14)
RED (#14)
MOTOR CONN
5A
FUSE
15A
FUSE
55
54
52
46
41
40
39
38
24
23
5
1
(CONTROL BOX PCB)
B
LA
C
K
(#14)
RE
D
(#14)
1
2
3
4
5
6
7
8
9 10 11 12
1
2
3
4
5
6
7
8
9 10 11 12
PCB CONN
N/C
SHUNT CONN
FIGURE 3-4.1: FR2E-SERIES ELECTRIC RAMP HARNESS DIAGRAM (SHEET 1 OF 2)