2 - 8
INSTALLATION
DECEMBER 2018
32DSSSK06.D
K-SERIES PUBLIC USE SERVICE MANUAL
f. Refer
to
Figure 2-9
. Cut excess wire from long cable, install heavy ring terminal, and then connect to side
solenoid. Verify that red wire from main circuit breaker (if applicable) is connected to positive solenoid pole.
RSM0044000
POSITIVE CONNECTION
BLOCK TERMINAL
GROMMET
4 AWG POWER CABLE
INSTALL BOOT (KIT 37152)
FIGURE 2-9: CABLE ROUTING
g. Connect 12" cable, with ring terminals, from positive battery terminal to main circuit breaker terminal.
3.
CONNECT CONTROL PENDANT
a. Refer
to
Figure 2-10
. Connect hand-held control pendant to six-pin connector at left side of baseplate and
secure cable with supplied bracket and cable clamps.
PENDANT INTERFACE
INTERLOCK INTERFACE
STRAIN RELIEF
CABLE CLAMP
BRACKET
FIGURE 2-10: STRAIN RELIEF KIT
b. Install wall portion of dovetail clip (pendant storage) in an appropriate and safe location near lift.
CAUTION
Be sure that harness does not interfere with any moving
parts, or binds against any parts, or is pinched in any way.