3 - 5
MAINTENANCE
DECEMBER 2018
32DSSK06.D
K-SERIES PUBLIC USE SERVICE MANUAL
5) Route the cable around the IRS pulley mount block bushing (#2). Verify that cable is routed between the
bushing tab and the point where the cable makes contact with the bushing. Install washer and hex nut over
bushing and cable assembly.
6) Continue to route the cable around grooved bearings #3, #4, and #5.
7) Route the cable down the length of the vertical arm assembly and around grooved bearing #6.
8) Assemble and secure the end of the IRS cable to the left side of the bridgeplate (#7) using a hex screw,
washer, bushing, and he nut. Be sure to install a hex nut on the inside of the inner rollstop.
9) Repeat for right side.
10) Reinstall pinch point shields removed in step 2.