INSTALLATION INSTRUCTIONS
FUEGO
MODEL
:
EIR3SF
WAC Lighting Headquarters WAC Lighting(Hongkong) WAC Lighting (Shanghai)
44 Harbor Park Drive Room A2 15/F United Center 14 Lane 299, Bi Sheng Road
Port Washington, NY 11050 95 Queensway HK, 999077 Shanghai 201204
www.waclighting.com www.waclighting.hk www.waclighting.com.cn
3
/
4
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
DIMMING ADJUSTMENT:
1. Use a Philips head screw driver to adjust the dimming dial.
(Fig. 8)
2. Rotate until the arrow on the dial is pointed at the desired
wattage. The wattage may be adjusted to the pre-existing
tabs or any value in between.
3. The lower the wattage, the dimmer the fixture will be
(
Fig. 8, 9 for EIR3SF-12ET wattage reference
)
* For EIR3SF-15EL wattage reference
BEAM ANGLE ADJUSTMENT:
1. Twist the Lens Holder to the middle vertical slot.
2. Move the Lens Holder Up/Down to any Beam Changing
Slots for desired beam angle.
3. Twist the Lens Holder into the desired Beam Angle
Changing Slot.
Note: Beam angle is pre-set to be 60°, 45°, 30°, and 15°
from bottom up.
AIMING ADJUSTMENT (MODEL EIR3SF-12ET ONLY):
1. Hold the Lens Assembly with two fingers and tilt it left or
right as required. (Fig. 10)
2. Lens Assembly will be fixed by a spring mechanism to the
desired angle full stop.
Note: Aiming adjustment applies for Model EIR3SF-12ET only,
EIR3SF-15EL is fixed at 0°