background image

Retain these instructions for future service and adjustments 

615 South Street, Garden City, NY  11530 

Tel: (516) 515-5000 Fax (516) 515-5050 

www.waclighting.com

 

INSTRUCTIONS  

: INVISILED™ PALETTE & AURA – 24V  

Models Series   

: LED-TC   

 

CAUTION:  

  Read all instructions before installing. 

  Always turn off power at fuse box prior to installation to prevent electrical shock. 

  Intended for indoor use.  Dry and damp locations.  

  For installation by a qualified electrician.  

  System is intended for installation in accordance with National Electric Code, and local regulations.  

  Consult with local inspector to assure compliance. 

 

INVISILED™

 

Palette & Aura

 Tape Lights have polarity for connection. 

  If a 1/2”x1/2” or greater cove or channel is not built-in, a Retrofit Channel may be necessary to conceal the tape 

lights or provide an extended surface for mounting or directing the light.  

 

Wiring and Installation: 

 
Please refer to installation diagrams shown on next page. 
 

1.  Determine the number of separately powered runs needed. Calculate the number of power supplies. 
                                                        

 

Min. / max. run length

 

6 inch / 40 ft per run

 

Current

 

100 mA/ft

 

Power consumption

 

1.5 Watts/ft

 

 

2.  Measure  the  length  of  each  run  and  round  it  off  to  the  nearest  6-inch  interval.  Determine  the  necessary 

quantities of 1-ft, 5-ft. 

3.    Count the number of turns in the runs. 
4.  If making lateral turns at angles other than 90°, determine the number of joiner cables necessary to make 

the lateral angles. 

5.  Connect the DC power supply to incoming 120V supply.  
 

Hard Wire 

  DC power supply must be installed away from heat sources and accessible for service 

  Enclosed DC power supply is UL listed. The power supply box has a separate line volt, and 

low  volt  wiring  compartments.  Trade  size  knock  out  are  provided  on  both  compartments. 
Connect building wires to like color DC power supply wires with wire nuts. Building ground 
wire my be green or un-insulated, and attaches to green wire from DC power supply box. 

 

 

 

Portable  

  24 Volts DC power supply plugs into standard 120 Volts 3 prong grounded outlet 

  Power supply must be installed away from heat sources 

  Class II output splices do not require enclosures 

 

6.  Connect the output of the DC power supply with the WAC controller (refer to the picture in the next page), 

then  connect  the  5  pins  female  connector  of  the  controller  to  the  5  pins  male  connector  of  the  InvisiLED 
tape

,

 to form straight lines or bend lengthwise around the installation surface;  

7.  Connect remaining sections using 1-ft and 5-ft sections of tape light or connectors.

 

6inch LED sections may 

be cut where indicated at the end of the run only. 

8.   On smooth surfaces, the included adhesive is sufficient in most applications. However if mounting surface 

is a porous or textured surface, then use a Mounting Clip every 6 inches to reinforce the installation. 

9.  Terminate each separately powered run with an end cap. Cut end caps or male end caps are the available 

choices for cut or uncut sections respectively. 

 
 

 

 

 
 

 

Reviews: