background image

                                                                                                                                                    1 /4 

Installation Instructions: 

WT-RT Recessed Flanged Track System 

 

Safety Instructions: 

 

1.  Read all of these instructions before installing the track system. 
2.  Turn off power at main switch before installing or modifying the system. 
3.  Do not install within six inches of any curtain or combustible materials. 
4.  Do not install less than 5 feet above a floor. 
5.  Do not install in damp or wet locations. 
6.  Do not install concealed, or extended through building walls. 
7.  Do not attempt to energize anything other than a track light fixture. 
8.  This track system shall only be supplied with two single 120V, 60Hz, 20amp branch circuits.  
9.  Do not load to more than 20 amps per circuit. Although track light systems may seem to operate 

acceptably, a dangerous overload of the neutral may occur and result in a risk of fire. 

10.  Check with a qualified electrician before wiring. 
11.  All of the installations shall be in accordance with NEC and all local codes. 
12.  Save these installation instructions and refer to them when additions or changes to the track 

configuration are made. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 

A:  Strap Mounting 
 

z

 

Remove the End Cap and save. 

z

 

Slide the perforated hanger straps

not 

included

can 

be purchased in a hardware 

store

 into the groove in the side of the track. 

An equal number of straps should be mounted 
on each side of the track. 

z

 

Wrap the straps around the building structure 
or nail the straps to the structure. They should 
be positioned evenly to balance the track. 

z

 

Placing

 one hanger strap every foot

per side 

is recommended. 

z

 

Push End Cap into the track at the end of the 
track and secure by screw. 

z

 

The hanger strap can be bought at a hardware 
store, recommend size is 11/16 inch (17mm) 
in width.

B: Direct Mounting 

 

z

 

Mounting slots in top of track can be knocked 
out and are spaced every 10 inches for 
convenience.  

z

 

Mounting as shown using a mounting screw 
every 2 feet is recommended. 

z

 

Additional supports may be added for heavier 
loaded applications. 

Generally, for any mounting method, do not exceed 4 feet between mounting points, and do not 

exceed 6 inches (for 4 feet 

of 

track or less in length) or 12 inches (for track that is greater than 4 feet) 

from each end of the single track section. Always use two or more mounting supports for each track 
length.

 

Mounting options  

Ceiling Channel 

Hanger Strap 

Ceiling Structure 

Mounting Screw 

Reviews: