background image

INSTALLATION INSTRUCTION 

InvisiLED Tunable White  

T24-TW3 

 

Waclighting.com 

Phone (800) 526.2588 

Fax       (800) 526.2585 

Headquarters/Eastern Distribution Center    

44 Harbor Park Drive  

Port Washington, NY 11050 

 

Central Distribution Center  

1600 Distribution Ct  

Lithia Springs, GA 30122  

Western Distribution Center 

1750 Archibald Ave  

Ontario, CA 91761  

 

 

  WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program

.                        Oct. 2022      

2. 

 

 

 

3. 

Measured a distance between power supply and DMX controller to the beginning of the tape run. Choose between two options below to wire 

the power and data communication to the tape. When choosing wire, factor in voltage drop, amperage rating, shield/unshielded, and type (in-wall 

rated).

 

 

Option A: Unshielded Cable 25 ft. maximum distance between power supply to the beginning of the tape 

The WAC In wall rated 20 AWG unshielded cable can be used to wire between a power supply-Wireless DMX LED Controller to the beginning of 

the tape up to 25 ft. Smaller gauge wire number (bigger conductor) can be used, but the maximum run length limitation remains at 25 ft. due data 

communication distortion if it’s run over 25 ft. (See FIG. 3) Wire color connection is shown in Table 1. 

 

 

   

Table. 1 

Wire Color Connection 

Wireless DMX LED Controller Terminal 

Color  

T24-EX3-* Cable  

Tape marking 

RED 

RED 

+24VDC (RED) 

WHITE 

WHITE 

DATA (WHITE) 

BLACK 

BLACK 

- (BLACK) 

 

    

FIG. 3 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Option B: Shielded data Cable 90 ft. maximum distance between power supply to the beginning of the tape 

A shield data cable shall be used to connect between the power supply-Wireless DMX LED Controller to the beginning of the tape up to 90 ft. (See 

FIG. 4) 

ICE cable model number: Control Yellow is recommended. Product information can be found below: 

https://www.icecable.com/products/control-yellow

 

https://icecable.s3.amazonaws.com/uber_products/specs/000/000/078/original/Control_Yellow.pdf?1435595602

 

For Plenum spaces, ICE cable Control Yellow Plenum is recommended. 

https://www.icecable.com/products/control-yellow-plenum

 

Both drain and common conductor wires shall be connected to a black terminal of Wireless DMX LED Controller. Another end shall be connected to 

the black wire of connector cable. The signal conductor shall be connected to the white terminal of Wireless DMX LED Controller. Another end shall 

be connected to the white wire of connector cable. The power cable can be either shielded or unshielded cable. The bigger conductor yields less 

voltage drop. The +24VDC polarity shall be connected to the red terminal on Wireless DMX LED Controller. Another end shall be connected to the 

red wire of connector cable. The -24VDC or common conductor wire shall be connected to a black terminal of Wireless DMX LED Controller. 

Another end shall be connected to the black wire of connector cable. (see FIG. 5) 

T24-B-WT (5-3 terminal box) may be used to connect between 5 wires of shield cable to 3 wires of InvisiLED tape connector.  

 

    

FIG. 4 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

Shielded Data Cable

 

90 FT MAX

 

Summary of Contents for InvisiLED T24-TW3

Page 1: ...closer than 6 in from any curtain or similar combustible material Do not modify or disassemble product beyond instructions or warranty will be void Failure to follow safety warnings and installation...

Page 2: ...TE BLACK BLACK BLACK FIG 3 Option B Shielded data Cable 90 ft maximum distance between power supply to the beginning of the tape A shield data cable shall be used to connect between the power supply W...

Page 3: ...e Black 4 To extend an unshielded cable length if needed In Wall Rated Joiner Cable T24 IC and Joiner Cable Extender T24 FF WT can be used to join between sections as shown in FIG 6 FIG 6 5 To extend...

Page 4: ...2300 0 2105 4 83 19 270 123 255 2400 0 1818 4 33 22 240 75 255 2500 0 1667 3 86 24 212 35 255 2600 0 1538 3 58 26 196 13 255 2700 0 1429 3 37 28 183 255 0 2800 0 1538 3 57 26 198 255 12 2900 0 1600 3...

Page 5: ...ution Center 1750 Archibald Ave Ontario CA 91761 WAC Lighting retains the right to modify the design of our products at any time as part of the company s continuous improvement program Oct 2022 5 In o...

Page 6: ...0 64 0 73 0 82 0 91 1 00 1 09 1 18 1 27 1 36 1 45 1 54 1 63 1 72 1 81 3200K 0 09 0 09 0 18 0 27 0 36 0 46 0 55 0 64 0 73 0 82 0 91 1 00 1 09 1 18 1 28 1 37 1 46 1 55 1 64 1 73 1 82 3300K 0 09 0 09 0 1...

Page 7: ...inch interval The cut line is shown on both sides of connector See FIG 11 FIG 11 9 Mount InvisiLED Tunable White tape light clean surface before mounting Peel off 3M VHB adhesive backing covers off as...

Page 8: ...022 8 Tape to Tape T Connector T24 TI WT See FIG 14 Tape to Tape X Connector T24 XI WT See FIG 15 FIG 14 FIG 15 1 Tape to Tape L Connector T24 LI WT See FIG 16 Flex Tape to Tape Y Connector T24 Y WT S...

Page 9: ...750 Archibald Ave Ontario CA 91761 WAC Lighting retains the right to modify the design of our products at any time as part of the company s continuous improvement program Oct 2022 9 SYSTEM DIAGRAM Inv...

Page 10: ...less voltage drop and boost light output up Another way is to lower a maximum DMX value to reduce the current consumption to InvisiLED TUNABLE WHITE tape Thus a contrast between beginning and the end...

Reviews: