OM 25-3503 us – Edition 4.1 * 2503_3503b330.fm
3-43
Operation
Protective Front Guard structure category I (option)
Option starting cabin no. 78626
DANGER
Danger of piercing/penetration by objects from the front!
Causes serious injury or death.
☞
Install a protective Front Guard structure in areas with danger from the
front, for example pipes, tree trunks, etc.
☞
Machine operation is prohibited without a protective Front Guard structure.
Information!
The protective Front Guard structure corresponds to category I according to ISO
10262:1998.
• The machine owner must ensure that the hazard situation is evaluated and that
the national regulations are observed.
• The machine owner must ensure that only work is performed that does not
require any higher protection.
• Accidents cannot be fully avoided despite equipping a machine with protective
structures.
1
Stop and park the machine. Stop the engine.
2
A minimum 2 persons are required for installing/removing.
3
Mounting point
A
(upper).
Fig. 120: Protective Front Guard structure (symbolic repre-
sentation)
Fig. 121: Upper mounting point
A