5-34
OM 25-3503 us – Edition 4.1 * * 2503_3503b530.fm
Maintenance
Putting into operation again
☞
Remove the grease from the piston rods.
☞
Install or connect the battery.
☞
Remove the seals from the exhaust pipe and the air filter intake.
☞
Check the condition of the air filter cartridges and replace them if necessary.
☞
If the machine was out of service for over 6 months, change the oil in the gearbox,
engine and other units.
☞
Also replace hydraulic oil filters (return and breather filters) if the machine has been out
of service for over 6 months.
☞
Lubricate the machine according to the lubrication plan.
☞
Add a little engine oil.
☞
Check the levels.
☞
Remove the cutoff solenoid from the engine.
☞
Let the engine run 10 seconds.
☞
Wait 1 minute.
☞
Let the engine run 10 seconds again.
☞
Fit the cutoff solenoid back on again.
☞
Start the engine and let it run without any load.