Labels
E 1100
24
wc_si000629gb.fm
425
425
To start the machine (I):
1. Check the level of the Heat Transfer Fluid. Also check the level of fuel
in the diesel fuel tank.
2. Connect the machine to the electric power source.
3. Move the circuit breaker switch to the ON position. Also press the ON/
OFF switch.
4. Set the temperature controller to 80°C (176°F).
5. Move the burner switch to the ON position.
6. Move the pump switch to the ON position.
7. Unlock the hose reel by turning the T-handle counterclockwise.
8. Unwind the hose and position it on the surface to be heated.
To shut down the machine (O):
1. Move the burner switch to the OFF position.
2. Set the temperature controller to less than 40°C (104°F).
3. Move the pump switch to the OFF position.
4. Move the hose rewind switch to the ON position, and rewind the hose.
5. Lock the hose by turning the T-handle clockwise.
6. Move the hose rewind switch to the OFF position.
7. Move the circuit breaker to the OFF position.
8. Disconnect the electric power supply.
Summary of Contents for 5000620172
Page 19: ...E 1100 Safety Information wc_si000628gb fm 19 Notes ...
Page 20: ...Labels E 1100 20 wc_si000629gb fm 2 Labels 2 1 Label Locations wc_gr009588 ...
Page 105: ...ghi_tx001153gb fm 105 E 1100 Maintenance ...
Page 122: ...Technical Data E 1100 122 wc_td000476gb fm 10 5 Dimensions cm in wc_gr008706 ...
Page 133: ...wc_tx001673gb fm 133 Fuji Temperature Controller ...
Page 134: ...wc_tx001673gb fm 134 Fuji Temperature Controller ...
Page 151: ...E 1100 Schematics wc_tx001908gb fm 151 11 3 Burner System Circuit ...
Page 152: ...Schematics E 1100 152 wc_tx001908gb fm 11 4 Circulation System Circuit ghi_gr005662 ...
Page 153: ...E 1100 Schematics wc_tx001908gb fm 153 11 5 Rewind System Circuit ...
Page 158: ...Schematics E 1100 158 wc_tx001908gb fm 11 10 Genset DC Wiring Diagram ...
Page 160: ......
Page 161: ......