E 1100
Operation
4.26
Operating at High Elevations
Background
If using the machine at or above elevations of 1524 m (5000 ft.) asl, the load on the
generator must be reduced to maintain efficient engine performance. Reduced load
can be acheived by temporarily removing a fuse located within the generator
enclosure.
Requirements
Machine stopped
Control switches off
Engine stopped and breaker switch off
Standard tools
Procedure
Perform the procedure below to reduce the load on the generator when operating
at or above elevations of 1524 m (5000 ft.) asl.
1. Remove the bolts
(a)
on the E-stop panel.
2. Carefully pull the panel away from the enclosure a small distance to allow
access to the E-stop switch
(b)
mounted in the panel.
3. Push the release tab
(c)
in the direction of the arrow to detach the switch, then
remove the panel.
4. Twist and remove the fuse holder
(d)
.
5. Pull the fuse
(e)
out of the holder.
NOTICE:
Retain the fuse for future use.
6. Reinstall the fuse holder and E-stop switch.
7. Reinstall the E-stop panel.
Result
The load on the genarator will be reduced upon starting the machine.
wc_gr009668
a
c
b
d
e
Summary of Contents for 5000620172
Page 19: ...E 1100 Safety Information wc_si000628gb fm 19 Notes ...
Page 20: ...Labels E 1100 20 wc_si000629gb fm 2 Labels 2 1 Label Locations wc_gr009588 ...
Page 105: ...ghi_tx001153gb fm 105 E 1100 Maintenance ...
Page 122: ...Technical Data E 1100 122 wc_td000476gb fm 10 5 Dimensions cm in wc_gr008706 ...
Page 133: ...wc_tx001673gb fm 133 Fuji Temperature Controller ...
Page 134: ...wc_tx001673gb fm 134 Fuji Temperature Controller ...
Page 151: ...E 1100 Schematics wc_tx001908gb fm 151 11 3 Burner System Circuit ...
Page 152: ...Schematics E 1100 152 wc_tx001908gb fm 11 4 Circulation System Circuit ghi_gr005662 ...
Page 153: ...E 1100 Schematics wc_tx001908gb fm 153 11 5 Rewind System Circuit ...
Page 158: ...Schematics E 1100 158 wc_tx001908gb fm 11 10 Genset DC Wiring Diagram ...
Page 160: ......
Page 161: ......