E 1100
Accessories
wc_tx001844gb.fm
69
5.2
Expanding the Surface Heating Capacity
Background
The E 1100 can be combined with additional hose(s) and pump(s) to increase the
surface heating capacity.
The Wacker Neuson HHS 1101 is a Hold Handling System (HHS) that contains one
hose loop of 1100 feet.
The Wacker Neuson HHS 2202 is a Hold Handling System (HHS) that contains two
hose loops of 1100 feet each.
The Wacker Neuson Single Pump Pack (SPP) is used with the HHS 1101.
The Wacker Neuson Dual Pump Pack (DPP) is used with the HHS 2202.
The typical configurations are shown below.
Estimated
capacities
The E 1100 is capable of the following when utilizing the expansion configurations
illustrated below.
Option 1
E 1100 combined with one HHS 1101
(a)
and one SPP
(b)
. For detailed
information, see topic
Expanded Operation Using One SPP and One HHS 1101
.
Option
Description
Application Area
Thaw
Cure
Frost
Prevention
1
1 HHS 1101, 1 SPP
m
2
(ft
2
)
204
(2200)
408
(4400)
610
(6600)
2
1 HHS 2202, 1 DPP
m
2
(ft
2
)
Not
applicable
610
(6600)
915
(9900)
wc_gr008454
Summary of Contents for 5000620172
Page 19: ...E 1100 Safety Information wc_si000628gb fm 19 Notes ...
Page 20: ...Labels E 1100 20 wc_si000629gb fm 2 Labels 2 1 Label Locations wc_gr009588 ...
Page 105: ...ghi_tx001153gb fm 105 E 1100 Maintenance ...
Page 122: ...Technical Data E 1100 122 wc_td000476gb fm 10 5 Dimensions cm in wc_gr008706 ...
Page 133: ...wc_tx001673gb fm 133 Fuji Temperature Controller ...
Page 134: ...wc_tx001673gb fm 134 Fuji Temperature Controller ...
Page 151: ...E 1100 Schematics wc_tx001908gb fm 151 11 3 Burner System Circuit ...
Page 152: ...Schematics E 1100 152 wc_tx001908gb fm 11 4 Circulation System Circuit ghi_gr005662 ...
Page 153: ...E 1100 Schematics wc_tx001908gb fm 153 11 5 Rewind System Circuit ...
Page 158: ...Schematics E 1100 158 wc_tx001908gb fm 11 10 Genset DC Wiring Diagram ...
Page 160: ......
Page 161: ......