E 1100
Accessories
wc_tx001844gb.fm
71
5.3
Expanded Operation using One SPP and One HHS 1101
Requirements
Machine stopped
One HHS 1101 Hose Handling System
One SPP Single Pump Pack
Procedure
Perform the procedure below to expand the machine with one Hose Handling
System (HHS) and one Single Pump Pack (SPP).
1. Position the E 1100 near the application area.
2. Unwind and position the hose
(a)
from the E 1100 hose reel within the
application area.
3. Unwind and position the hose
(b)
from the HHS 1101
(c)
within the application
area. Place the HHS 1101 frame in a safe place.
4. Connect the male quick connect (QC) of hose
(b)
to the accessory return port
(d)
of the E 1100.
5. Connect the female QC of hose
(b)
to the male supply port of the SPP
(e)
.
6. Connect the leader hose of the SPP to the accessory supply port
(f)
.
7. Connect the electric cord of the SPP to the duplex receptacle of the E 1100.
Result
The machine is now ready for expanded operation.
wc_gr008517
a
b
d
c
e
f
Summary of Contents for 5000620172
Page 19: ...E 1100 Safety Information wc_si000628gb fm 19 Notes ...
Page 20: ...Labels E 1100 20 wc_si000629gb fm 2 Labels 2 1 Label Locations wc_gr009588 ...
Page 105: ...ghi_tx001153gb fm 105 E 1100 Maintenance ...
Page 122: ...Technical Data E 1100 122 wc_td000476gb fm 10 5 Dimensions cm in wc_gr008706 ...
Page 133: ...wc_tx001673gb fm 133 Fuji Temperature Controller ...
Page 134: ...wc_tx001673gb fm 134 Fuji Temperature Controller ...
Page 151: ...E 1100 Schematics wc_tx001908gb fm 151 11 3 Burner System Circuit ...
Page 152: ...Schematics E 1100 152 wc_tx001908gb fm 11 4 Circulation System Circuit ghi_gr005662 ...
Page 153: ...E 1100 Schematics wc_tx001908gb fm 153 11 5 Rewind System Circuit ...
Page 158: ...Schematics E 1100 158 wc_tx001908gb fm 11 10 Genset DC Wiring Diagram ...
Page 160: ......
Page 161: ......